Power Optimizer


The SolarEdge power optimizer is a DC/DC converter which is connected by installers to each PV module or embedded by module manufacturers, replacing the traditional solar junction box. The SolarEdge power optimizers increase energy output from PV systems by constantly tracking the maximum power point (MPPT) of each module individually. Furthermore, the power optimizers monitor the performance of each module and communicate performance data to the SolarEdge monitoring portal for enhanced, cost-effective module-level maintenance. Each power optimizer is equipped with the unique SafeDC™ feature which automatically shuts down modules' DC voltage whenever the inverter or grid power is shut down.

The MPPT per module allows for flexible installation design with multiple orientations, tilts and module types in the same string.  When working with SolarEdge Inverters, SolarEdge power optimizers automatically maintain a fixed string voltage, allowing installers even greater flexibility with longer strings and strings of different lengths in order to design optimal PV systems. The SolarEdge power optimizers are compatible with c-Si and thin-film modules and have a 25 year warranty.

The following power optimizer models are available:

 

P-Series Module Add-On Power Optimizer

Connected by installers to the PV module and compatible with a wide range of modules

Power Optimizer Model

Module Power

Module Voc 

P300*                                               

≤300W

≤48V

P350*

≤350W

≤60V

P370*

≤370W

≤60V

P500*

≤500W≤80V

P404*

≤405W

≤80V

P405**

≤405W≤125V
* Also available with frames mounted in advance for quicker installation. Download datasheet
** Dual input for parallel connection of two modules; single input version is available and should be used when connecting a single module to the power optimizer (in case of odd number of modules in the string or when using modules that are compatible only in a single-module configuration)

 

P-Series Commercial Power Optimizer

Commercial solution connecting two modules per power optimizer

Power Optimizer Model

Module Power

Module Voc

P600                                                 

≤600W*

≤96V

P700

≤700W*

≤125V

P800p (for parallel connection)**

≤800W*

≤83V

P800s (for series connection)

≤800W*

≤120V

* Rated combined STC power of 2 modules connected in series. Module of up to +5% power tolerance allowed.
** Dual input for parallel connection of two modules; single input version is available and should be used when connecting a single module to the power optimizer (in case of odd number of modules in the string)

 

Module Embedded Power Optimizer

Embedded in each module by the module manufacturers, replacing the traditional solar junction box

Power Optimizer Model

Module Power 

Module Voc 

OPJ300-LV                                    

≤300W

≤55V

 

Read More

 

Feature highlights of SolarEdge Power optimizers:

  • Per-module Maximum Power Point Tracking (MPPT)
  • Superior efficiency (99.5% peak efficiency, 98.8% weighted efficiency) 
  • Mitigates all  types of modules mismatch-loss, from manufacturing tolerance to partial shading            
  • Designed for extreme environmental conditions
  • 25 year reliability and warranty
  • Advanced, real-time performance measurement
  • Automatic module DC voltage shut-down for installer and firefighter safety
  • Independent optimization technology (IndOP™) - allows operation with any inverter and requires no additional interface hardware
  • Embedded by module manufacturers, or connected by installers to c-Si and thin-film modules
  • Available with frames mounted in advance for quicker installation

 

Related documents